Serviceline Industrial Sensors
Support en ligne pour la protection contre le risque d’explosion

Non disponible à la vente

Ce produit a été remplacé.Trouver un produit de replacement HiC2441
Non disponible à la vente
Non disponible à la vente

SMART Universal Barrier HiC2441

HiC2441
  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Analog input, digital input,
    analog output, digital output
  • No configuration required, device is self-adapting
  • HART transparency
  • Low power dissipation
  • 3-way isolation
  • Up to SIL 2 acc. to IEC 61508 in preparation

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Téléchargez ici la fiche technique complète en PDF ::


Caractéristiques techniques  HiC2441

General specifications
Signal typeUniversal
Supply
ConnectionSL1: 1a(-), 1b(-); 2a(+), 2b(+)
Rated voltage19 ... 30 V DC via Termination Board
Ripple≤ 10 %
Rated current≤ 30 mA
Power consumption≤ 700 mW
Analog input
Suitable field devices2-wire SMART transmitters, current sources
Signal0/4 ... 20 mA , limited to approx. 40 mA (depends on control system) , reverse polarity protected
Field circuitSL2: 5a(+), 5b(-) (2-wire SMART transmitter)
SL2: 5a(+), 1b(-) (2-wire SMART transmitter with current source)
Voltage dropapprox. 4 V (current source)
Control circuitSL1: 8a(+), 7a(-)
Supply voltagemin. 16 V at 20 mA (2-wire SMART transmitter)
Voltage15 ... 30 V
Signal0/4 ... 20 mA , sink mode , working voltage 15 ... 30 V
Ripple20 mV rms
Analog output
Suitable field devicesI/P converters (positioner), on-site-displays
Signal0/4 ... 20 mA
Field circuitSL2: 5a(+), 5b(-)
Load0 ... 650 Ω
Voltage≥ 13 V at 20 mA
Ripple20 mV rms
Control circuitSL1: 8a(+), 7a(-)
Voltage12 ... 30 V
Signal0/4 ... 20 mA
Line fault detection> 100 kΩ at max. 30 V, with field wiring open
Digital input
Field circuitSL2: 5a(+), 1a(-) (NAMUR sensor)
SL2: 5a(+), 5b(-) (dry contact)
Suitable field devicesNAMUR sensors according to IEC/EN 60947-5-6, dry contacts
Signal0.1 ... 9 mA , sink mode
Open loop voltageapprox. 10 V DC , 1 kΩ series resistance
Signal0.1 ... 9 mA
Control circuitSL1: 8a(+), 7a(-)
Voltage13 ... 30 V
Digital output
Field circuitSL2: 5a(+), 5b(-)
Suitable field devicessolenoid valves, acoustic or visual alarms
Drive capability12 V / 40 mA at 300 Ω load
Internal resistormin. 240 Ω
Current limit45 mA
Open loop voltageapprox. 22 V
Control circuitSL1: 8a(+), 7a(-)
Voltage1-signal: 19 ... 30 V DC
0-signal: 0 ... 5 V DC
Current1-signal: 0 ... 45 mA, depending on the output load
0-signal: < 0.1 mA, independent of the output load
Power dissipation1.1 W at 24 V, 300 Ω load (digital output)
Transfer characteristics
Deviationat 20 °C (68 °F)
≤ ±20 µA incl. linearity, hysteresis and supply fluctuations at 4 ... 20 mA (analog input, analog output)
≤ ±60 µA incl. linearity, hysteresis and supply fluctuations at 0 ... 45 mA (digital output)
Influence of ambient temperature< 2 µA/K (0 ... 60 °C (32 ... 140 °F))
< 3 µA/K (-40 ... 0 °C (-40 ... 32 °F))
Switching frequency≤ 500 Hz with 50 % duty cycle (digital input, NAMUR sensor)
≤ 5 Hz (digital input, dry contact)
≤ 20 Hz (digital output)
Frequency rangeHART: bandwidth by 0.5 Vpp signal and/or 1 mApp signal 950 ... 2500 Hz (analog input, analog output)
Settling time≤ 20 ms (analog input, analog output)
≤ 1 ms (digital input, NAMUR sensor)
Reaction time≤ 5 ms , turn-on/turn-off time (digital output)
Galvanic isolation
Control/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Protection against electrical shockIEC 61010-1:2010
InputEN 60947-5-6:2000
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Mechanical specifications
Degree of protectionIP20
Massapprox. 100 g
Dimensions12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch)
Height128 mm
Width12.5 mm
Length106 mm
Mountingon termination board
Codingpin 1 and 4 trimmed
For further information see system description.
Data for application in connection with hazardous areas
EU-type examination certificateTÜV 14 ATEX 153522 X
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
Supply
Maximum safe voltage250 V (Attention! The rated voltage can be lower.)
EquipmentSL2: 5a(+), 5b(-)
Voltage25.2 V
Current110 mA
Power693 mW
Internal capacitance5.7 nF
Internal inductance0 mH
EquipmentSL2: 5a(+), 1b(-)
Voltage< 28 V
Current< 115 mA
Voltage7.2 V
Current0 mA
Power0 mW
Internal capacitance5.7 nF
Internal inductance0 mH
EquipmentSL2: 5a(+), 1a(-)
Voltage12.6 V
Current13 mA
Power41 mW
Internal capacitance5.7 nF
Internal inductance0 mH
CertificateTÜV 14 ATEX 153523 X
MarkingEx-Hexagon II 3G Ex nA II T4 Gc [device in zone 2]
Galvanic isolation
Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
IECEx approvalIECEx TUN 15.0004X
Approved for[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Ex nA II T4 Gc
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210107
ECLASS 12.027210107
ECLASS 11.027210107
ECLASS 10.0.127210107
ECLASS 9.027210107
ECLASS 8.027210107
ECLASS 5.127210107
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: HiC2441

Product Documentation: HiC2441

Language Selection:
Safety and Security DocumentationLangueType de fichierTaille
Manuel d'instructionsFRAPDF165 KB
Functional Safety ManualENGPDF341 KB
Manuals
System ManualENGPDF5438 KB

Design / Simulation: HiC2441

Language Selection:
CADLangueType de fichierTaille
CAD 2-D / CAD 2-DALLZIP16364 KB
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ13 KB
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.